Changzeyuan Electronics' busbar heat shrink tubing for LV/HV switchgear and motor busbars, with matching red/yellow/green insulation tubing: environmentally friendly, low smoke, RoHS compliant; good insulation and flexibility; minimum shrink temperature 110 °C; voltage ratings CZY 1T: 1 kV, CZY 10M: 10 kV; excellent insulation, temperature and voltage resistance.
Busbar heat shrink tubing for LV/HV switchgear and motors, with matching red/yellow/green insulation tubing is made from radiation cross-linked modified polyolefin with other additives.
Applications:Busbar heat shrink tubing for LV/HV switchgear and motors, with matching red/yellow/green insulation tubingBusbar insulation in LV/HV switchgear: prevents injury from live bare busbars; avoids short circuits and flashover caused by small animals or conductive objects; prevents corrosion, contamination and flashover; increases insulation margin and allows shorter phase-to-phase and phase-to-earth clearances, enabling more compact switchgear designs.
Shrink ratios: 2:1 and 2.5:1
Product details:
Product: CZY 1 kV / 10 kV busbar heat shrink tubing
Sizes: Ø20–Ø150
Products Size: Ф20-Ф150
Models: CZY 1 kV, CZY 10 kV
Products Type: CZY 1KV ,CZY 10KV
Features:
★ Environmentally friendly, low smoke, RoHS compliant;
★ Good insulation and flexibility;
★ Minimum shrink temperature 110 °C;
★ Voltage ratings: CZY-1KV, CZY-10KV
★ Colours: red, yellow, green, black
Applications:Widely used for busbar insulation in LV/HV switchgear: prevents injury from live bare busbars; avoids short circuits and flashover caused by small animals or conductive objects; prevents corrosion, contamination and flashover; increases insulation margin and allows more compact switchgear designs.
| Item | Test method | Specification |
| Radial shrinkage | ASTM D2671 | 50% |
| Longitudinal change | ASTM D638 | ≤±5% |
| Tensile strength | ASTM D638 | ≥10.0Mpa |
| Elongation at break | ASTM D638 | ≥200% |
| Heat ageing test | 150℃/168h | Tensile strength after heat ageing at 158 °C, 168 h |
| Volume resistivity | ASTM D876 | ≥1.0X1014Ω·cm |
| Dielectric strength | ASTM D2671 | ≥19KV/MM |
| Heat shock | 200℃±3℃/4h | No cracking, dripping or flowing |
| Water absorption | ASTM D570A | ≤0.5% |
CZY-BT 1 kV busbar tubing standard sizes
| Size | As supplied (mm) | After full recovery (mm) | ||
| Min ID (D) | Wall (T) | Max ID (D) | Wall (T) | |
| Φ15/8 | 15 | 0.35±0.4 | 12 | 0.7±0.4 |
| Φ20/10 | 20 | 0.40±0.4 | 12 | 0.8±0.4 |
| Φ30/15 | 30 | 0.4±0.4 | 17 | 0.8±0.4 |
| Φ35/17.5 | 35 | 0.4±0.4 | 19 | 0.8±0.4 |
| Φ40/20 | 40 | 0.4±0.4 | 21 | 0.8±0.4 |
| Φ50/25 | 50 | 0.5±0.4 | 27 | 1.0±0.4 |
| Φ60/30 | 60 | 0.5±0.4 | 31 | 1.0±0.4 |
| Φ70/35 | 70 | 0.5±0.4 | 36 | 1.0±0.4 |
| Φ80/40 | 80 | 0.5±0.4 | 41 | 1.0±0.4 |
| Φ90/45 | 90 | 0.6±0.4 | 46 | 1.2±0.4 |
| Φ100/50 | 100 | 0.6±0.4 | 51 | 1.2±0.4 |
| Φ120/60 | 120 | 0.8±0.4 | 61 | 1.6±0.4 |
| Φ150/75 | 150 | 0.8±0.4 | 76 | 1.6±0.4 |
CZY-BT 10 kV busbar tubing standard sizes
| Size | As supplied (mm) | After full recovery (mm) | ||
| Min ID (D) | Wall (T) | Max ID (D) | Wall (T) | |
| Φ20/10 | 20 | 1.0±0.4 | 12 | 2.0±0.4 |
| Φ30/15 | 30 | 1.0±0.4 | 17 | 2.0±0.4 |
| Φ35/17.5 | 35 | 1.0±0.4 | 19 | 2.0±0.4 |
| Φ40/20 | 40 | 1.0±0.4 | 21 | 2.0±0.4 |
| Φ50/25 | 50 | 1.0±0.4 | 27 | 2.0±0.4 |
| Φ60/30 | 60 | 1.0±0.4 | 31 | 2.0±0.4 |
| Φ70/35 | 70 | 1.0±0.4 | 36 | 2.0±0.4 |
| Φ80/40 | 80 | 1.0±0.4 | 41 | 2.0±0.4 |
| Φ90/45 | 90 | 1.0±0.4 | 46 | 2.2±0.4 |
| Φ100/50 | 100 | 1.0±0.4 | 51 | 2.2±0.4 |
| Φ120/60 | 120 | 1.0±0.4 | 61 | 2.2±0.4 |
| Φ150/75 | 150 | 1.0±0.4 | 76 | 2.2±0.4 |